Description
FIBARO Flood Sensor is a universal, Z-Wave compatible, flood and temperature sensor. Device can be battery or VDC powered. Flood alarm is sent to the Z-Wave network devices or additionally to any alarm system controller, through opening a NC contact.
The device has built in temperature sensor, monitoring temperature of e.g. floor. Flood Sensor is designed to be placed on the floor or on a wall with a flood sensor probe extended by connected wire. The device has built in visual LED indicator and acoustic alarm. LED diode signals flood, operating mode or the Z-Wave network communication range.
In addition, the sensor is equipped with a tilt sensor reporting tilt or movement to the main controller e.g. when someone has taken the Sensor from its original location.
FIBARO Flood Sensor is sink-proof, which means it drifts on the water surface and keeps on sending alarm signal in case of substantial inundation of water.
Features
- Compatible with any Z-Wave Controller
- Compatible with any Z-Wave or Z-Wave+ Controller (firmware 3.2 or higher)
- Supports protected mode (Z-Wave network security mode) with AES-128 encryption (firmware 3.2 or higher).
- May be connected to any alarm system (potential free output terminal)
- Extremely easy installation – simply put on a surface prone to flooding
- May be installed anywhere – flood sensor’s contacts extended with a wire
- Battery or VDC powered. When connected to an external, 12/24V DC power source, the battery serves as an emergency power source
- Theft protection – tilt is reported to the Z-Wave network or alarm system’s main controller
- Two operating modes – flood/temperature sensor or just a temperature sensor.
- Alarm is signalled by sound, visual indicator (LED diode) and Z-Wave
Technical data
Power supply: | Battery or 12–24V DC supply (LPS or NEC class 2) |
Battery type: | CR123A battery, 3.0V DC |
Power consumption (at VDC operation) | 0.4W |
Output terminals maximum current carrying capacity: (ALARM NC, TAMP NC) |
25mA |
Maximum voltage at output terminals: (SMOKE NC, TAMP NC) |
24V DC / 20V AC |
EU standards compliance: | R&TTE 1999/5/EC RoHS 2011/65/EU |
Radio protocol: | Z-Wave Z-Wave+ (firmware 3.2 or higher) |
Radio frequency: | 868.4 or 869.8 MHz EU; 908.4 or 916.0 MHz US; 921.4 or 919.8 MHz ANZ; 869.0 MHz RU; |
Range: | up to 50 m outdoors up to 30 m indoors up to 40 m indoors (firmware 3.2 or higher) (depending on terrain and building structure) |
Operational temperature: | 0°C to 40°C – battery powering mode -20°C to 70°C – VDC powering mode |
Measured temperature range: | -20°C to 100°C |
Temperature measuring accuracy: | 0.5°C (within 0 – 40°C range) |
Dimensions (diameter x height): | 72 x 28mm |